TC5000 Series Inverted Microscope Instruction Manual

Strany 2 - Table of Contents

The image below designates the main components of the TC5300 Series Phase Contrast Inverted Microscope. 1. Binocular Head, 30° Inclination 2. Eyep

Strany 3

The image below designates the main components of the TC5500 Epi- Fluorescence Inverted Microscope. 1. Binocular Head, 30° Inclination 2. Eyepiece

Strany 4 - 1.1 Microscope Features

2.1 Installation Site The microscope should be operated in a room with as little dust as practically possible. Keep your instrument away from solvent

Strany 5

2.3 Microscope Set Up • As a first step, remove all components from the shipping container and remove the packing materials. Save the container and

Strany 6

• If purchased, un-wrap the mechanical stage (MA380/05). Locate the two holes on the bottom side of the plain stage on the right hand side. The two t

Strany 7 - 1.6 Warranty Notes

2.4 Installing the Phase Contrast Slider These instructions are only to be followed if you currently have a Model TC-5100, TC-5200, TC-5500 and TC-56

Strany 8

2.5 Installing Fluorescence Option The following assembly steps are not required if fluorescence accessories have NOT been purchased. Prior to instal

Strany 9

3. Next, remove the fluorescence access cover on the back of the microscope as shown in Figure 2a using a #2 Phillips screwdriver removing all seven

Strany 10

12. When installed correctly, the fluorescence filter carriage will slide easily and click and lock in all three positions. When using the microsc

Strany 11

2.6 Fluorescence Filter Information The epi-fluorescence equipped TC-5500 and TC-5600 include the following filter sets: Excitation Type Exciter Fi

Strany 12 - Operating Ambient Conditions

Table of Contents 1.0 Introduction 1.1 Microscope Features 1.2 General Safety Guidelines 1.3 Warning/Caution symbols used in this manual 1.4 Int

Strany 13 - 2.3 Microscope Set Up

3.0 Operation Once the microscope has been setup in its working location with all of the components correctly installed, it is ready for use. Your T

Strany 14

3.1 Basic Set Up For Transmitted Light – Brightfield 1. First, set your interpupillary distance on the microscope eyetubes by pulling them apart or

Strany 15 - Contrast

Objectives Information Depending on which objective is being used, before turning the nosepiece to change magnifications, the nosepiece will need to b

Strany 16

3.2 Transmitted Light Operation – Phase Contrast Phase contrast is a very useful technique for high-contrast images of unstained or transparent spec

Strany 17

Possible Phase Contrast Mode Operational Problems If normal adjustments are not getting the results you expect, check these: • Wrong phase annulus

Strany 18

3.3 Incident Light Operation: Epi-Fluorescence For microscopes with fluorescence option installed only. For viewing of transparent objects using i

Strany 19

Possible Incident Light Fluorescence Operational Problems If normal adjustments are not getting the results you expect, check these: • Weak fluores

Strany 20

3.4 UV Light Safety Considerations Mercury arc lamps have UV light content in their output. The U.S. National Institute for Occupational Safety and

Strany 21

3.5 Photomicrography with 35mm SLR and Digital SLR Cameras The TC Series of microscopes have a camera port directly in front of the instrument. In o

Strany 22

3.6 Photomicrography with Digital Still Cameras In order to mount a consumer grade digital camera to this microscope, an optional camera attachment M

Strany 23

TC-5000 Series Inverted Biological Microscope 1. Introduction The Meiji Techno TC-5000 Series inverted biological microscopes have a slim compact de

Strany 24

4.0 Maintenance and Cleaning • Disconnect the power cord on your equipment prior to performing cleaning, maintenance or repair. • Keep electrica

Strany 25

Cleaning of Glass Surfaces Use a soft brush or lint-free cotton cloth to removed dust and loose particles. For tough dirt, use a soft lint-free cott

Strany 26

5.0 Troubleshooting Meiji Techno products are manufactured in Japan under ISO9000 manufacturing standards. However, if you ever have any difficulty w

Strany 27

5.1 Replacing the mains fuse on the microscope ALWAYS DISCONNECT YOUR EQUIPMENT BEFORE DOING ANY REPAIR. Location of Mains Fuse The mains fuse of

Strany 28

5.3 Replacing the 6V 30W Halogen Light ALWAYS DISCONNECT YOUR EQUIPMENT BEFORE DOING ANY REPAIR. Do not touch the glass envelope of the lamp durin

Strany 29

5.4 Fluorescence Lamp does not work LAMP HOUSE MAY BE HOT TO THE TOUCH. Do not touch the glass envelope of the lamp at any time. Keep the protecti

Strany 30 - 4.0 Maintenance and Cleaning

6.0 Storage Protect your microscope from dust after each use by covering your instrument with the protective dust cover that came with your microscop

Strany 31 - Cleaning the Objectives

8.0 Accessories and Replacements Parts Part numbers and product descriptions for accessories and parts for TC Series Inverted Microscopes can be foun

Strany 32 - 5.0 Troubleshooting

Epi-Fluorescent Objectives - Planachromat - Infinity Corrected - F = 200mm MA849 TC Planachromat F4X objective ∞/1.0, NA: 0.13, WD = 17.5mm, F.L.= 50.

Strany 33

MA860 ND25 Neutral density filter for epi-illuminator (included with TC5500, TC5600)

Strany 34

1.1 Microscope Features • CAD Designed Frame and Optics • Slim Compact Footprint • Infinity Corrected Optical System • Low Positioned Ergonomic C

Strany 35

9.0 Technical Descriptions Filters and Applications Filter ND25 ND13 Green Interference LB100 G533 Cobalt Blue Application Ne

Strany 36

10.0 Physical Dimensions

Strany 37 - Viewing Heads

Meiji Techno Co. Ltd. MEIJI TECHNO AMERICA 3010 Olcott St Santa Clara, CA 95054 Toll free: Phone: Fax: Email: Web: (800) 832-0060

Strany 38

1.3 Warning/Caution Symbols Used in this Manual You must be aware of all safety issues when you install and operate this microscope system. Several w

Strany 39

1.5 Product Safety Information- Handling the Microscope This microscope is not intended to be used in the immediate vicinity of w

Strany 40 - Filters and Applications

1.6 Warranty Notes Meiji Techno warrants this product against defects in material and/or workmanship for the life of the instrument from the date of

Strany 41

Meiji Techno’s convenience. In some cases, requests for warranty service are received which are not justified. In these cases, Meiji Techno will provi

Strany 42

2.0 The Microscope and its Components The image below designates the main components of the TC5100 Series Brightfield Inverted Microscope. 1. Bino